Construction [?save.pdf]
|
Conductor |
Material |
CCS |
|
Diameter |
1.02mm ± 0.02 mm |
|
|
Wire Gauge |
18 AWG |
|
|
Insulation |
Material |
FPE |
|
Diameter |
4.57 mm ± 0.2 mm |
|
|
AL Foil |
Construction |
With Foil |
|
Material |
AP |
|
|
Width |
18 mm |
|
|
thickness |
> 0.024 mm |
|
|
Overlap Rate |
≥ 20% |
|
|
Braid |
Material |
AL |
|
Diameterr |
0.12 mm |
|
|
Braid Coverage |
60% - 98% |
|
|
Jacket |
Material |
PVC |
|
Diameter |
7.0 mm ± 0.5 mm |
|
|
Power Conductor |
Material |
CCA |
|
Diameter |
7 x ( 0.3 mm ± 0.02 mm ) |
|
|
Power Insulation |
Material |
PE |
|
Diameter |
2 x ( 1.6 mm ± 0.02 mm ) |
|
|
Power Jacket |
Material |
PVC |
|
Diameter |
3.2 mm ± 0.3 mm |
Packing
|
Package length |
100m / 300m / 500m |
|
Customized |
|
|
Box type |
Ordinary / Waterproof |
|
Customized optional |
Test Data
|
Dielectric Strength |
Not breakdown with 2kV DC for 1 min |
|
Sheath Strength |
Not breakdown with 3kV |
|
Characteristic Resistance |
75Ω ± 5Ω |
|
Insulation Resistance |
5000MΩ/km |
|
Elongation at Break (Wire) |
≥15% |
|
Elongation at Break (Sheath) |
≥150% |
|
Low Temperature Bending |
Not cracked |
|
Thermal Shock |
Not cracked |
|
Operating Temperature |
–20°C to +60°C (–4°F to 140°F) |
|
Storage Temperature |
–10°C to +40°C (14°F to 104°F) |
Certifications and Standards
|
Certification |
CPR Eca |
|
Executive Standards |
Q/DXJ 194-2020 |
Technical Test [Attenuation @68°F(20°C)]
|
Frequency(MHZ) |
Maximum(dB/100ft) |
Maximum(dB/100m) |
|
5 |
0.58 |
1.90 |
|
55 |
1.60 |
5.25 |
|
187 |
2.85 |
9.35 |
|
300 |
3.55 |
11.64 |
|
450 |
4.40 |
14.43 |
|
600 |
5.10 |
16.73 |
|
750 |
5.65 |
18.54 |
|
865 |
6.10 |
20.01 |
|
1000 |
6.55 |
21.49 |
|
1450 |
7.98 |
26.16 |
|
1800 |
8.46 |
27.73 |
|
2250 |
10.38 |
34.03 |
|
3000 |
11.44 |
37.50 |